Accessories
iMarine Airconditioning Accessories
Please use the links below to read more details about our wide range of quality products and accessories for the marine industry. If you would like to speak to one of our professional team or send us an enquiry, then please use our contact form.
Teak Timber Grills
| T12X6RA | 12" x 6" Teak Return Air Grill | ![]() |
| T16X4RA | 16" x 4" Teak Return Air Grill | |
| T1OX1ORA | 10" x 10" Teak Return Air Grill | |
| T12X12RA | 12" x 12" Teak Return Air Grill | |
| T10X6DA | 10" x 6" Teak Discharge Air Grill | |
| T12X6DA | 12" x 6" Teak Discharge Air Grill | |
| T16X4DA | 16" x 4" Teak Discharge Air Grill | |
Cherry Timber Grills
| T12X6RA | 12" x 6" Cherry Return Air Grill | ![]() |
| T16X4RA | 16" x 4" Cherry Return Air Grill | |
| T1OX1ORA | 10" x 10" Cherry Return Air Grill | |
| T12X12RA | 12" x 12" Cherry Return Air Grill | |
| T1OX6DA | 10" x 6" Cherry Discharge Air Grill | |
| T12X6DA | 12" x 6" Cherry Discharge Air Grill | |
| T16X4DA | 16" x 4" Cherry Discharge Air Grill | |
* All timber grills are painted with a clear semi gloss finish.
* All timber grills can be supplied in custom sizes
* All timber grills can be supplied in different types of timber
e.g. Rock Maple, Beech, Ash, Oak
* Timber discharge air grills are constructed from solid timber with two
sets of vertical and horizontal moveable louvers
* Timber return air grills are constructed from solid timber with one set of fixed timber horizontal louvers and filter
Plastic Grills
| RBPDG4 | 4" Round Beige Plastic Discharge Grill w/shut off |
|
| RBPDG6 | 6" Round Beige Plastic Discharge Grill w/shut off | |
| RBLPDG3 | 3" Round Black Plastic Discharge Grill w/shut off | |
| RWHPDG3 | 3" Round White Plastic Discharge Grill w/shut off | |
![]() |
||
* Roundplastic 4" & 6" discharge grills are available in beige and designed to shut off for head installation
* Round plastic 3" discharge grills are available in black & white and designed with rotatable blades for helm dash installation
Installation Guideline
Flexible Insulated Ducting
| FID3 | 3" Flexible Insulated Ducting per metre |
| FID4 | 4" Flexible Insulated Ducting per metre |
| FID5 | 5" Flexible Insulated Ducting per metre |
| FID6 | 6" Flexible Insulated Ducting per metre |
| FID7 | 7" Flexible Insulated Ducting per metre |
| FID8 | 8" Flexible Insulated Ducting per metre |
| FID10 | 10" Flexible Insulated Ducting per metre |

Inadequate air flow is a leading cause of complaints and can significantly shorten the life of the Marvair unit. The air distribution system must be engineered to ensure sufficient air flow throughout the system. This includes proper duct sizing and sufficient open area on the supply and return grills.
Duct work guidelines
•
Duct work must be firmly attached, secured and sealed to prevent air leakage.
•
Use transition boxes and air divider boxes with duct to split and route the conditioned
air as required.
•
When using insulated flexible duct, make sure that the inner duct is secured and sealed
to an adapter before pulling the insulation over the connection.
•
Install the supply air grills high on cabin wall to create good air circulation.
•
Stretch the duct tight in straight runs.
•
Make the bends and turns as large as possible. Secure the duct so that is remains in its
installed position.
•
Always use insulated duct to prevent condensation.
•
Insulate all transition and air divider boxes.
•
If duct is in a storage or other high traffic area, protect it from being crushed by a
shield or box.
•
If the duct must be run through areas containing engines or fossil fuelled devices,
it is absolutely mandatory that the duct system be air tight to prevent carbon monoxide
and any other hazardous gases or vapours from being introduced into the air system.
Air Flow Noise
Air moving though duct work and across the blades in the grills and louvers generates sound.
The faster the air, the greater the sound. To keep sound to acceptable levels, the cross sectional area of the duct must be large enough to keep the velocity below 600ft/min (3m/sec). Air flow faster than this is likely to cause noise complaints.
Grill Transition Boxes
| GTB10X6 | 10" x 6" Grill Transition Box Only | ![]() |
| GTB12X6 | 12" x 6" Grill Transition Box Only | |
| GTB16X4 | 16" x 4" Grill Transition Box Only | |
Grill Transition Boxes With 1 Hose Adapter
| GTBHA10X6 | 10" x 6" Grill Transition Box w/1 Hose Adapter | ![]() |
| GTBHA12X6 | 12" x 6" Grill Transition Box w/1 Hose Adapter | |
| GTBHA16X4 | 16" x 4" Grill Transition Box w/1 Hose Adapter | |
All transition boxes can be supplied fitted with any 1 hose adapter available
Air Divider Boxes
| ADB5.5 | 5 ½" Air Divider Box Only | ![]() |
| ADB6.5 | 6 ½" Air Divider Box Only | |
| ADB7.5 | 7 ½" Air Divider Box Only | |
Air Divider Boxes With 3 Hose Adapters
| ADBHA5.5 | 5 ½" Air Divider Box w/3 Hose Adapters | ![]() |
| ADBHA6.5 | 6 ½" Air Divider Box w/3 Hose Adapters | |
| ADBHA7.5 | 7 ½" Air Divider Box w/3 Hose Adapters | |
Hose Adapters
| HAR3 | 3" Hose Adapter Round |
|
| HAR4 | 4" Hose Adapter Round | |
| HAR5 | 5" Hose Adapter Round | |
| HA05 | 5" Hose Adapter Oval | |
| HAR6 | 6" Hose Adapter Round | |
| HA06 | 6" Hose Adapter Oval | |
| HAR7 | 7" Hose Adapter Round | |
| HA07 | 7" Hose Adapter Oval | |
| HAR8 | 8" Hose Adapter Round | |
| HA08 | 8" Hose Adapter Oval | |
![]() |
||
P3 Panel Insulated Transition and Air Divider Boxes can be supplied to custom made sizes
Electric Damper
| ED6 | 6" Electric Damper 240V 50Hz | ![]() |
| ED8 | 8" Electric Damper 240V 50Hz | |
Magnetic Pump
* Non-corrosive polypropylene housing
* Non leak seal-less motor chamber
* Ceramic durable shaft and bearing
240V 50Hz |
@2M Head | |
| MDZ40 | 240V 50/60 Hz Sea Water pump | 20 LPM |
| MDZ55 | 240V 50/60 Hz Sea Water pump | 35LPM |
| MDZ70 | 240V 50/60 Hz Sea Water pump | 50LPM |
| NHZ250PS | 240V 50/60 Hz Sea Water pump | 75LPM |
115V 60Hz |
||
| MD40 | 115V 60 Hz Sea Water pump | 20 LPM |
| MD55 | 115V 60 Hz Sea Water pump | 35 LPM |
| MD70 | 115V 60 Hz Sea Water pump | 50 LPM |
| NH250PS | 115V 60 Hz Sea Water pump | 75 LPM |
Water Flow Chart
Minimum Water Flow* for Marvair Reverse Cycle systems |
|
| Model (BTUH) | Minimum Water Flow at the Unit |
| 5,000 | 1.4 GPM / 5.3 LPM |
| 7,000 | 2.0 GPM / 7.6 LPM |
| 10,000 | 2.9 GPM / 11.0 LPM |
| 12,000 | 3.5 GPM / 13.3 LPM |
| 16,000 | 4.7 GPM / 17.8 LPM |
| 18,000 | 5.25 GPM / 19.9 LPM |
| 24,000 | 7.0 GPM / 26.5 LPM |
* Based upon 85°F (29.5°C) inlet water measured at the inlet of the Marvair unit. |
|

All Purpose Sea Water Hose
| SWH12 | ½"All Purpose Sea Water Hose per metre | ![]() |
| SWH16 | ⅝"All Purpose Sea Water Hose per metre | |
| SWH19 | ¾"All Purpose Sea Water Hose per metre | |
| SWH25 | 1"All Purpose Sea Water Hose per metre | |
| SWH32 | 1¼"All Purpose Sea Water Hose per metre | |
| SWH40 | 1½"All Purpose Sea Water Hose per metre | |
| Recommended Water Pipe Sizes | ||
| Flow Rate (GPM) | Pump Inlet Pipe Size |
Pump Discharge Pipe size |
| 1 through 4 | ⅝" |
⅝" |
| 4 through 7 | ¾" |
⅝" |
| 7 through 11 | 1" |
¾" |
| 11 through 15 | 1" |
1" |
| 15 through 20 | 1¼" |
1" |
| 20 through 25 | 1¼" |
1¼" |
| 25 through 30 | 1½" |
1¼" |
COOLING WATER FLOW DISTRIBUTION MANIFOLDS

Proper water flow is absolutely critical to the operation of the Marvair reverse cycle air conditioner. If the pipe is too small, back pressure is created causing a drop in water flow, even if the pump is correctly sized. If the piping is too large, the slow velocity of the water may cause silt build-up and barnacle growth inside the piping, eventually restricting water flow.
![]()
Home | Products | Discontiued | Accessories | Location | Contact Us












